B-63323EN-1/03 1.AXIS CONTROL
- 205 -
1912 Dead zone for the synchronous error on each axis
9" %"
.,==
3 % """""% *"
%""(
)% ""#(
1913 Maximum permissible synchronous error for synchronous error alarm 2
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] 1 - 32767
Specify the maximum permissible synchronous error for synchronous
error alarm 2.
Specify this parameter only for a slave axis.
1914 Maximum permissible synchronous error for synchronous error alarm 1
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] 1 - 32767
Specify the maximum permissible synchronous error for synchronous
error alarm 1.
Specify this parameter only for a slave axis.
1915 Compensation gain of the synchronous error for each axis
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 1 - 1024
The gain of synchronous error compensation is set.
As many pulses as the number of compensation pulses for every 8-msec
sampling period, obtained from the following equation, are output to
the slave axis.
This setting is made for the slave axis only.
1024
Ci
error ationsynchronizpulses onCompensati ×=
Ci: Compensation gain