1.AXIS CONTROL B-63323EN-1/03
- 20 -
Mirror image check signal
MMI1<F65#0>, MI2<F69#0>, ...
[Classification] Output signal
[Function] These signals indicate the mirror image condition of each axis. The
mirror image is set by taking the logical sum of the signal from the MDI
panel and the input signal of the machine tool, then relaying the
information to the machine tool.
These signals are provided for every control axis; the numeral in the
signal name indicates the relevant control axis number.
MMIx
x : 1 ..... Mirror image is applied to the 1st axis
2 ..... Mirror image is applied to the 2nd axis
3 ..... Mirror image is applied to the 3rd axis
: :
[Output condition] These signals turn to "1" when:
- Mirror image signal MIn of the corresponding axis is "1"; or
- Mirror image of the corresponding axis is turned on by setting
data from the MDI panel.
These signals turn to "0" when:
- Mirror image signal (MIn) of the corresponding axis is "0" and the
setting of the mirror image in the control unit is turned off.
- Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G065 MI1
F065 MMI1
The above addresses are the signal addresses for the first axis.
For the signal addresses for the second axis and subsequent axes, see
the Appendix A.1.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
0012 MIR