B-63323EN-1/02 5.AUTOMATIC OPERATION
- 477 -
2. In simultaneous automatic and manual operation
a) Command pulses are not output for automatic operation.
b) Command pulses are output for manual operation.
This signal is valid when bit 6 (MLE) of parameter No. 1005 is set to 1.
All-axis machine lock check signal
MMLK<F004#7>
[Classification] Output signal
[Function] Reports the state of the all-axis machine lock signal.
[Output condition] This signal is set to 1 in the following case:
- When all-axis machine lock signal MLK is set to 1
This signal is set to 0 in the following case:
- When all-axis machine lock signal MLK is set to 0
Machine lock check signal for each axis
MMLK1<F065#1>, MMLK2<F069#1>,...
[Classification] Output signal
[Function] Reports the state of each axis-by-axis machine lock signal.
MMLKx
x : 1 -State of the axis-by-axis machine lock signal for the first axis
x : 2 -State of the axis-by-axis machine lock signal for the second axis
x : 3 -State of the axis-by-axis machine lock signal for the third axis
:
[Output condition] This signal is set to 1 in the following case:
- When all-axis machine lock signal MMLKx is set to 1
This signal is set to 0 in the following case:
- When all-axis machine lock signal MMLKx is set to 0
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G004 MLK
F004 MMLK
#7 #6 #5 #4 #3 #2 #1 #0
G065 MLK1
F065 MMLK1
The address above is the signal address for the first axis.
For the signal addresses for the second axis and subsequent axes, see
the address table in Appendix A.1.