2.PREAPARATIONS FOR OPERATION B-63323EN-1/03
- 322 -
2.5 INTERLOCK
General
This signal disables machine movement along axes. When this signal
is input during movement along axes, the tool movement is decelerated,
then stopped.
Signal
All axes Interlock signal
*IT<G000#0>
[Classification] Input signal
[Function] This signal is used to inhibit the machine from moving, and is effective
regardless of the selected mode.
[Operation] When the *IT signal is set to 0, movement along the axes is decelerated
and stopped, regardless of the mode that is set. During automatic
operation, however, this stop state occurs without changing the
automatic operation mode (with the STL signal set to 1, and the SPL
signal set to 0).
Fig. 2.5 (a) Block containing only axis move command
(manual and automatic operation)
Fig. 2.5 (b) Block containing auxiliary functions only
(automatic operation)
Command read
Axis move
*IT
Command read
MF/SF/TF/BF
FIN
*IT