B-63323EN-1/03 1.AXIS CONTROL
- 77 -
a, b, c, d : Compensation point numbers. (Pitch error compensation
point numbers are used. Parameters Nos. 5461 to 5464)
α, β, γ, ε: Compensation amounts at compensation points a, b, c, and d
(parameters Nos. 5471 to 5474)
In Fig. 1.3.8 (a), a, b, c, and d are 1, 3, 60, and 126, respectively.
In Fig. 1.3.8 (a), the compensation amounts at the individual
compensation points located between points a and b are (β-α) / (b - a).
Parameter
5461 Gradient compensation point number a for each axis
5462 Gradient compensation point number b for each axis
5463 Gradient compensation point number c for each axis
5464 Gradient compensation point number d for each axis
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 to [128 * (number of control axes) – 1]
From 0 through 1279 or from 0 through 3071 depending on the
number of controlled axes is less than or equal to 10 or greater than
10, respectively.
Set a gradient compensation point. A compensation point to be set
becomes a compensation number in stored pitch error
compensation.
5471 Compensation α at gradient compensation point number a for each axis
5472 Compensation β at gradient compensation point number b for each axis
5473 Compensation γ at gradient compensation point number c for each axis
5474 Compensation δ at gradient compensation point number d for each axis
8
-'%4%-'%4%
Set a compensation for each compensation point.