B-70265EN/02 APPENDIX E.PARAMTER LIST
- 261 -
LHC
0: Does not control the oscillator with external signals (standard).
1: Controls the oscillator with external signals.
In the automatic operation mode, external signals are used to turn on
and off the shutter and beam output.
#7 #6 #5 #4 #3 #2 #1 #0
15002 PSH PCG ADC BMA
[Data type] Bit
BMA
0: Disables beam output with the shutter closed in the automatic
operation mode (standard).
1: Enables beam output with the shutter closed in the automatic
operation mode (for maintenance).
ADC
0: Uses the select signal to determine AD converter 2 data.
1: the DI signal to determine AD converter 2 data. (standard)
PCG When the machining condition setting function is used together with
G24:
0: High-speed piercing is not performed if no address is specified.
1: High-speed piercing is performed even if no address is specified.
PSH
0: Uses all discharge tubes.
1: Uses half of the discharge tubes.
#7 #6 #5 #4 #3 #2 #1 #0
15003 C60 TR1 TON IVT GVW HPT TIV
[Data type] Bit
TIV
0: Inverts the sign (+/-) of the amount of tracing displacement.
1: Does not invert the sign (+/-) of the amount of tracing
displacement.
HPT
0: Rewrites parameter settings for extending or shortening piercing.
1: Does not rewrite parameter settings for extending or shortening
piercing.
GVW
0: Disables evacuation when RUN is turned off (for maintenance).
1: Enables evacuation when RUN is turned off (standard).
IVT The oscillator is:
0: Not equipped with an inverter.
1: Equipped with an inverter.
TON The oscillator is:
0: Not equipped with a turbo blower.
1: Equipped with a turbo blower.
TR1 The number of turbo blowers to be used is:
0: Two.
1: One.