E.PARAMTER LIST APPENDIX B-70265EN/02
- 294 -
E.14 PARAMETERS FOR LASER POWER / VOLTAGE DROP
15270 Discharge tube voltage in normal operation
[Data type] Word
[Unit of data] V
[Valid data range] 0 to 32767
Set the discharge tube voltage during normal base discharge.
This parameter is automatically rewritten after the discharge start
signal (G222#7 HVON) is turned on.
15271 Power decrease limit
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
If the difference between the specified output and actual output is
greater than this setting, low output alarm (No.4076) is issued.
15272 Discharge tube voltage decrease limit
[Data type] Word
[Unit of data] V
[Valid data range] 0 to 32767
If the difference between the discharge tube voltage during use of the
laser and that at the start-up of the laser is greater than this setting,
low voltage alarm (No.4088) is issued.
15276 Laser gas replacement time
[Data type] Word
[Unit of data] sec
[Valid data range] 0 to 32767
Time during which a new laser gas is filled in the internal piping
system after RUN is turned on