B-70265EN/02 3.INSTALLATION
- 39 -
(b) If not placing the cable in the duct
If not placing the power cable in the duct between the
power board and the laser oscillator, you can use a heavy-
duty power cord cable.
C1000-E
OSC Recommendation
Hitachi Cable : 600V 2PNCT
Cross Section
22mm
89A
Diameter
28mm
Max
LAPP : OLFLEX 100 25mm
25.4mm
93A
C2000-E
Hitachi Cable : 600V 2PNCT 38mm
124A
34mm
LAPP : OLFLEX 100 50mm
φ
34.5mm
146A
C4000-E
LAPP : OLFLEX 100 95mm
41.3mm
217A
C5000-E
Hitachi Cable : 600V 2PNCT 100mm
253A
24mm
LAPP : OLFLEX FD-90 120mm
23.8mm
219A
C6000-E
Hitachi Cable : 600V 2PNCT 125mm
291A
26mm
LAPP : OLFLEX FD-90 185mm
φ
28.9mm
285A
4 Core
Sheathed
Portable
1 piece
Cross Section Diameter
Type Layout
3 Core
Sheathed
Portable
1 piece
Cross Section
Diamete
1 Core
Sheathed
Portable
4 pieces
Cross Section
Diameter
(c) Recommended cable suppliers
Hitachi Cable : Hitachi Cable, Ltd.
Furukawa: The Furukawa electric Co., Ltd.
LAPP : U.I. Lapp GmbH
(2) Ground cable
Connect the ground cable to the ground connection section
(Class 1 : Ground resistance is 10 ohms or less.)
(3) Signal cables
(a) When a metallic cable is used:
Use a metallic cable for connections over a distance of less
than 10 m.
Connect the cable to connector JD1B on the IF PCB, and
set jumper pin LINK1 to JD1 on the IF PCB.
(b) When an optical fiber cable is used:
Use an optical fiber cable for CE-marked machines or for
connections over a distance of 10 m or more.
Connect the cable to connector COP1B on the IF PCB, and
set jumper pin LINK1 to COP on the IF PCB.
(4) Signal lines
(a) Emergency stop input signals (ESP1, ESP2)
(b) OFF prohibit signals (OFI1, OFI2) - CNC side (EOF,
COM) : A contact
(c) Laser power supply ON/OFF signal (CP1A) - CNC-
controlled 24 VDC