FANC Series 16i/18i/21i-TB, Spindle Synchronous Control, Specifications Additional Manual Page 16

Additional Manual
SYW The next block operation of G51.8 command that is starting spindle synchronous
control.
0 : It Is performed as soon as PSYFN signal was set to 1.
1 : It is performed after the synchronize is completer with spindle synchronous control
and the phase matching is competed with spindle phase synchronous control.
4810 Error pulse between two spindles when synchronizing phases in the serial spindle
synchronization control mode
[Data type] Byte
[Unit of data] Pulse
[Valid data range] 0 to 255
Set the difference in error pulse between two spindles when synchronizing phases in the
serial spindle synchronization control mode. When the difference in error pulse between
two spindles is within the value set in this parameter , the spindle phase
synchronization completion signal FSPPH becomes 1.
This parameter is used to check the difference in phase in synchronization control and to
confirm the completion of synchronization in the serial spindle synchronization control
mode.
4811 Allowable error count for the error pulses between two spindles in the serial
spindle synchronization control mode
[Data type] Word
[Unit of data] Pules
[Valid data range] 0 to 32767
Set the allowable error count for the error pulses between two spindles in the serial
spindle synchronization control mode.
This parameter is used for the output phase error monitoring signal SYCAL that is
detected phase error between the two spindles in the serial spindle synchronization
control mode. When phase error between the two spindles was greater than the value set
in this parameter, SYCAL signal is set to 1.
Edit
16
/
17
A-78807E
Drawing No.
Page
Date
Design
Descri
p
tion
Date
2004/07/02
Design
K.Yamamuro
Approv.
FANUC Series 16i/18i/21i-TB
Spindle synchronous control
Title

Contents Summary of FANC Series 16i/18i/21i-TB, Spindle Synchronous Control, Specifications Additional Manual

  • Page 1FANC Series 16i/18i/21i-TB Spindle synchronous control Specifications FANUC Series 16i/18i/21i-TB Title Spindle synchronous control Drawing No. A-78807E Page Edit Date Design Description 1/17 Date 2004/07/02 Design K.Yamamuro Approv.
  • Page 21. Outline This function enables the synchronous control of two spindles. It also enables the control of rotation phase of a spindle, allowing non-standard workpieces as well as rods to be held by either of the two spindles. Spindle synchronous control has two control ways, ones is contoroles by PMC
  • Page 3Master spindle and slave spindle of spindle synchronous control was set in parameter No.1812 and No.1813. It is available to set 1 pair of master spindle and slave spindle that is performed spindle synchronous control on each path. PMC DO signal PSYON (F0348#0) is outputted by G51.8 command. Please
  • Page 4Spindle synchronous off by DI signal PSYRL G51.8 command PSYON PMC operation PMC operation finish (set spindle direction etc) PSYFN spindle synchronous action PSYRL Phase shift amount change in spindle synchronous control by program command G51.8 command PSYON PMC operation PMC operation finish (set
  • Page 5Starting next block command (case of the parameter No.4802#1 SYW=0) G51.8 command PSYON PMC operation PMC operation finish (set spindle direction etc) PSYFN spindle synchronous action next block command Starting next block command (case of the parameter No.4802#1 SYW=1) G51.8 command PSYON PMC opera
  • Page 6Note G51.8 and G50.8 command have to command in independently block. It is available to command without address R command. If you need to change phase shift amount in condition of spindle phase synchronous control mode, please execute G51.8 R_ command again. It it not able to use spindle synchronous
  • Page 7Supplementary explanation It becomes spindle phase synchronous control by G51.8 command with address R. When the error pulse difference between the two spindles is equal to or less than the value of parameter No.4810, spindle phase synchronous control completion signal is output. Spindle phase synch
  • Page 8It is available to command spindle speed after completion to start spindle synchronous control or spindle phase synchronous control same as S4/5 digits for master spindle. Also it is available to use PMC signal SIND, SSIN, SSGN, R01I-R12I,*SSTP,SOR etc as usual. You can control spindle speed from PM
  • Page 94. Signal Spindle synchronous control signal SPSYC [Classification] Input signal [Function] Specifies switching to spindle synchronization mode [Operation] When this signal set to 1, spindle synchronization mode is set. When this signal set to 0, spindle synchronization mode is cancelled. Note This
  • Page 10NOTE 1. When the two spindles seize the same workpiece, a spindle may be fixed at a position slightly displaced from the specified position because the two spindles are mechanically connected. In this case, an excessively high current can flow because the velocity loop integral function attempts to
  • Page 11Spindle synchronous control release signal PSYRL [Classification] Input signal [Function] Specify to release spindle synchronous control. On spindle synchronous control by program command function (G51.8), turn on this signal to release spindle synchronous control from PMC signal. [Operation] When t
  • Page 12This signal set to 0 when any of the following conditions is satisfied. The two spindles have not reached the speed corresponding to a specified spindle synchronous speed on spindle synchronization mode. The speed difference between the two spindles is greater than the value set in parameter No.4033
  • Page 13Note Even if this signal is set to 1 once, this signal is set to 0 when the speed difference becomes equal to or greater than the value set in parameter No.4033 for a cause such as cutting load variation. Phase error monitoring signal SYCAL [Classification] Output signal [Function] Posts that the er
  • Page 147 6 5 4 3 2 1 0 F0044 SYCAL FSPPH FSPSY 7 6 5 4 3 2 1 0 F0348 PSYON Please see the parameter manual of AC spindle for the details about time chart. FANUC Series 16i/18i/21i-TB Title Spindle synchronous control Drawing No. A-78807E Page Edit Date Design Description 14/17 Date 2004/07/02 Design K.Yama
  • Page 155. Parameter 4800 SYM ND4 ND3 ND2 ND1 [Data type] Bit ND1 In controlling the spindle synchronization, the direction of the first spindle motor rotation is:. 0 : The direction indicated by the command sign. 1 : The opposite direction to that indicated by the command sign. ND2 In controlling the spind
  • Page 16SYW The next block operation of G51.8 command that is starting spindle synchronous control. 0 : It Is performed as soon as PSYFN signal was set to 1. 1 : It is performed after the synchronize is completer with spindle synchronous control and the phase matching is competed with spindle phase synchron
  • Page 174812 Maser spindle in spindle synchronous control 4813 Slave spindle in spindle synchronous control [Data type] Byte [Valid data range] 0,1 to number of spindles or m*10+n (m:1 to number of paths, n:1 to number of spindles) Set the slave spindle and master spindle for spindle synchronous control. Se