1998/ 5/26
Synchronization cancellation
Synchronization
cancellation M command
Deceleration
(movement)
Synchronization mode
signal (Fx197)
CN
PMC
Completion signal
(FIN : Gx004#3)
PM
CN
)
Miscellaneous function
strobe signal (MF : Fx007#0)
CN
PM
Flexible synchronous control
mode select signal (Gx197)
PM
CN
Command sequence
1) The tool is moved away from the workpiece at cancellation.
2) When M code for turning off the flexible synchronous control
mode is specified, and flexible synchronous control mode select
signal (Gx197) which corresponds to the M code is set to 0,
synchronization cancellation start.
3) When deceleration starts, synchronization mode signal (Fx197)
is set to 0.
4) Return completion signal (FIN).
Note
1 Linear acceleration/deceleration is applied to synchronization
start/cancellation.
2 When a parameter of the time constant (No.13425~13428) is
set to 0, acceleration/deceleration is not executed.
3 The next block is not executed until the movement o
deceleration is finished during an automatic operation.
Edit
12/30
Data Si
nature
Descri
tion
Flexible synchronous control Specifications
A-63540EN
Drawing No.
Page
2004/08/10 H.Minami
Whole revision E.Genma
04
05
2004/08/19
ddition of (5)
FANUC Series 16i/18i - MB/TB, 18i - MB5
Title