1998/ 5/26
6 Signal
Flexible synchronous control mode select signals
MTA, MTB, MTC, and MTD <Gx197#0 to #3>
[Classification] Input signal
[Function] Select flexible synchronous control.
[Operation] 1) Synchronization is started by setting these signals to 1.
2) Synchronization is canceled by resetting these signals to 0.
MTA: Selects synchronization for group A.
MTB: Selects synchronization for group B.
MTC: Selects synchronization for group C.
MTD: Selects synchronization for group D.
Automatic phase synchronization signals
AUTPHA, AUTPHB, AUTPHC, and AUTPHD <Gx381#0 to #3>
[Classification] Input signal
[Function] Select automatic phase synchronization.
[Operation] 1) Automatic phase synchronization is not performed by setting
these signals to 0.
2) Automatic phase synchronization is performed after acceleration
which is applied to synchronization start is finished by setting
these signals to 1.
AUTPHA: Selects automatic phase synchronization for group A.
AUTPHB: Selects automatic phase synchronization for group B.
AUTPHC: Selects automatic phase synchronization for group C.
AUTPHD: Selects automatic phase synchronization for group D.