1998/ 5/26
Parameters of skip function
6200 SRE HSS
[Data type] Bit
HSS 0: The skip function does not use high-speed skip signals.
1: The skip function uses high-speed skip signals.
SRE When a high-speed skip signal is used:
0: The signal is considered to be input at the rising edge (0 to 1).
1: The signal is considered to be input at the falling edge (1 to 0).
6208 9S8 9S7 9S6 9S5 9S4 9S3 9S2 9S1
[Data type] Bit
9S1~9S8 Specify which high-speed skip signal to be enabled for the G31.8
command. The bit correspond to signals as follows:
9S1 ----- HDI0
9S2 ----- HDI1
9S3 ----- HDI2
9S4 ----- HDI3
9S5 ----- HDI4
9S6 ----- HDI5
9S7 ----- HDI6
9S8 ----- HDI7
Set each bit as follows:
0: The corresponding skip signal is invalid.
1: The corresponding skip signal is valid.
6220 Period during which input is ignored for high-speed skip signal
[Data type] Byte
[Unit of data] 8 ms
[Valid Data range] 3 ~ 127 (x 8 ms)
If a value falls outside this range is specified, 3 (x 8ms) is assumed.
This parameter specifies the period that must elapse between a
high-speed skip signal being input and input of the next high-speed
skip signal being enabled. This parameter is used to ignore chattering
in skip signals.
Edit
25/30
Data Si
nature
Descri
tion
Flexible synchronous control Specifications
A-63540EN
Drawing No.
Page
2004/08/10 H.Minami
Whole revision E.Genma
04
05
2004/08/19
ddition of (5)
FANUC Series 16i/18i - MB/TB, 18i - MB5
Title