1998/ 5/26
Phase synchronization end signals
PHFINA, PHFINB, PHFINC, and PHFIND
<Fx381#0 to #3>
[Classification] Output signal
[Function] Inform that automatic phase synchronization is finished.
[Operation] The signal becomes “1” when:
Automatic phase synchronization is finished.
The signal becomes “0” when:
Synchronization mode signals (Fx197) is set to 0.
PHFINA: Inform the finish of phase synchronization for group A.
PHFINB: Inform the finish of phase synchronization for group B.
PHFINC: Inform the finish of phase synchronization for group C.
PHFIND: Inform the finish of phase synchronization for group D.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Gx197 MTD MTC MTB MTA
#7 #6 #5 #4 #3 #2 #1 #0
Gx381 AUTPHD AUTPHC AUTPHB AUTPHA
#7 #6 #5 #4 #3 #2 #1 #0
Fx197 MFSYND MFSYNC MFSYNB MFSYNA
#7 #6 #5 #4 #3 #2 #1 #0
Fx381 PHFIND PHFINC PHFINB PHFINA