1998/ 5/26
4 SKIP FUNCTION FOR FLEXIBLE SYNCHRONOUS CONTROL
(Only for M SERIES)
4.1 General
This function provides the capability that skip function or high speed
skip function can be commanded for the slave axis in the flexible
synchronous control mode.
The features are as follows.
The program block to enable the function is not interrupted until
the total number of skip signal inputs reaches a value specified
in the same block.
The machine coordinate position of the slave axis at each time of
the signal inputs is stored in one of consecutive custom macro
variables.
The top number of the variables is specified in the block.
The total number of the inputs is stored in another specified
variable.
This function needs “Skip function for flexible synchronous control”
option.
FANUC Series 16i/18i - MB/TB, 18i - MB5
Title
4.2 Format
G31.8 is a one-shot G code.
During the execution of the G31.8 block, the machine coordinate
positions of the slave axis at the skip signal inputs are stored in the
consecutive custom macro variables where the top number of the
variables is specified by P and the maximum allowable number of the
skip signal inputs is specified by Q.
Mxx (flexible synchronous control mode on)
G31.8 G91 α0 P_ Q_ R_ ; (skip command for
flexible synchronous control)
P: The top number of the consecutive custom macro variables in
which the machine coordinate positions of the slave axis at the
skip signal inputs are stored.
α: The slave axis
Q: The maximum allowable number of the skip signal inputs.
(Range of command value: 1~200)
R: The number of the custom macro variables in which the total
number of the inputs is stored.
This data is usually the same as the value specified by Q.
Therefore this is not necessarily specified. Specify it when the
total number should be confirmed.
Edit
16/30
Data Si
nature
Descri
tion
Flexible synchronous control Specifications
A-63540EN
Drawing No.
Page
2004/08/10 H.Minami
Whole revision E.Genma
04
05
2004/08/19
ddition of (5)