1998/ 5/26
Parameters of Automatic
phase synchronization
5669 PHD PHC PHB PHA
[Data type] Bit
PHA Automatic phase synchronization for flexible synchronous control in
group A is:
0: Disabled.
1: Enabled.
PHB Automatic phase synchronization for flexible synchronous control in
group B is:
0: Disabled.
1: Enabled.
PHC Automatic phase synchronization for flexible synchronous control in
group C is:
0: Disabled.
1: Enabled.
PHD Automatic phase synchronization for flexible synchronous control in
group D is:
0: Disabled.
1: Enabled.
13420 DID DIC DIB DIA
[Data type] Bit
DIA Direction of movement for automatic phase synchronization
in group A
0: Positive (+) direction
1: Negative (-) direction
DIB Direction of movement for automatic phase synchronization
in group B
0: Positive (+) direction
1: Negative (-) direction
DIC Direction of movement for automatic phase synchronization
in group C
0: Positive (+) direction
1: Negative (-) direction
DID Direction of movement for automatic phase synchronization
in group D
0: Positive (+) direction
1: Negative (-) direction
This parameter is applied to rotation axis only.
Edit
22/30
Data Si
nature
Descri
tion
Flexible synchronous control Specifications
A-63540EN
Drawing No.
Page
2004/08/10 H.Minami
Whole revision E.Genma
04
05
2004/08/19
ddition of (5)
FANUC Series 16i/18i - MB/TB, 18i - MB5
Title