1998/ 5/26
7 Alarm and message
No. Message Meaning of data
5242 ILLEGAL AXIS NUMBER This alarm is caused by one of the following:
(This alarm is issued when flexible synchronization is turned
on.)
(1) The axis number of the synchronous master axis or slave
axis is incorrect.
(2) When Flexible synchronous control between path is not
used, the axis number of the slave axis is smaller than that
of the master axis.
(3) The parameter FWC (No.1802#7)is set to 0, when the
following function is used. Set FWC to 1.
- Flexible Synchronous Control in T-Series.
- Flexible Synchronous Control for between path
(4) When Flexible synchronous control between path is used,
the relation of master and slave axes loops.
(5) When Automatic phase synchronization is used, the
combination of master and slave axis is as follows.
Master: linear axis, slave: rotation axis (A type)
Master: rotation axis (A type), slave: linear axis or
rotation axis (B type)
Master: rotation axis (B type), slave: rotation axis (A
type)
(6) When Automatic phase synchronization is used, the
amount of a shift per one rotation (Parameter No.1260) of
the master axis differs from the one of the slave axis.
5244 TOO MANY DI ON Even when an M code was encountered in automatic operation
mode, the flexible synchronization mode signal was not driven
on or off. Check the ladder and M codes.
5245 OTHER AXIS ARE
COMMANDED
The following command conditions was present during flexible
synchronization or when flexible synchronization was turned
on:
(1) Both the master axis and its slave axis, which is in
synchronization with the master axis, happen to be the
same EGB axis. (M-Series)
(2) Both the master axis and its slave axis, which is in
synchronization with the master axis, happen to be the
same chopping axis. (M-Series)
(3) The reference position return mode is entered (or has
been entered).
When Flexible synchronous control between path is used,
(1) Over travel alarm occurs on slave axis
(2) Servo alarm occurs on the path in flexible synchronization
(3) Emergency stop condition occurs on the path in flexible
synchronization
Edit
29/30
Data Si
nature
Descri
tion
Flexible synchronous control Specifications
A-63540EN
Drawing No.
Page
2004/08/10 H.Minami
Whole revision E.Genma
04
05
2004/08/19
ddition of (5)
FANUC Series 16i/18i - MB/TB, 18i - MB5
Title