1998/ 5/26
2.3 Caution
1) When this function is used, set FWC (bit 7 of parameter No.
1802) to 1 (The processing of command multiplication (CMR) is
performed before acceleration/deceleration after interpolation).
If FWC is 0, the PS5242 alarm is issued when the flexible
synchronization mode is turned from off to on.
2) When over travel alarm occurs on slave axis, both master and
slave axes stop and the PS5245 (OTHER AXIS ARE
COMMANDED) alarm is issued in master axis path.
3) If servo alarm occurs, the flexible synchronization mode is
automatically turned off and the PS5245 (OTHER AXIS ARE
COMMANDED) alarm is issued in both paths of master axis and
slave axis.
4) When emergency stop condition occurs, the flexible
synchronization mode is automatically turned off and the PS5245
(OTHER AXIS ARE COMMANDED) alarm is issued in a path
which is not in emergency stop condition
5) When G28, G30, G30.1, G27, G29 or G53 is commanded for
slave axis, the PS010 (IMPROPER G CODE) alarm is issued.
When G28 is commanded for master axis and when a return to
the reference position has not been performed since the power
was turned on, the PS090 (REFERENCE RETURN
INCOMPLETE) alarm is issued.
6) This function is disabled in the following function:
- High-speed remote buffer A
- High-speed remote buffer B (M-Series)
- High-speed linear interpolation (M-Series)
- High-speed cycle machining
- AI contour control (M-Series)
- AI nano contour control
- High-precision contour control
- AI high-precision/AI nano high-precision contour control
Edit
9/30
Data Si
nature
Descri
tion
Flexible synchronous control Specifications
A-63540EN
Drawing No.
Page
2004/08/10 H.Minami
Whole revision E.Genma
04
05
2004/08/19
ddition of (5)
FANUC Series 16i/18i - MB/TB, 18i - MB5
Title