PROGRAMMING
B–63844EN/02
11. AUXILIARY FUNCTION
117
When a value is specified after address B, the code signal and strobe signal
are output. The code is retained until a B code is specified next.
The functions are used for machine side operations such as indexing for
the rotation axis. Each block can contain only one B code. Setting
parameter No. 3460 enables the use of one of addresses A, C, V, and W,
instead of address B. However, this address must be different from that
for the controlled axis. For details, refer to the manual issued by the
machine tool builder.
0 to 99999999
1. To enable the use of a decimal point, set bit 0 (AUP) of parameter
No.3450 to 1.
Command Output value
B10. 10000
B10 10
2. Use bit 0 (DPI) of parameter No. 3401 to specify whether the
magnification for B output will be 1000 or 1 when a decimal
point is omitted.
Command Output value
DPI=1 B1 1000
DPI=0 B1 1
3. Use bit 0 (AUX) of parameter No. 3405 to specify whether the
magnification for B output will be 1000 or 10000 when a
decimal point is omitted for the inch Input system
(only when DPI=1).
Command Output value
AUX=1 B1 10000
AUX=0 B1 1000
The address (B or the address specified with parameter No. 3460) used
with the second auxiliary functions cannot be used for the controlled axis
name (parameter No. 1020).
11.3
THE SECOND
AUXILIARY
FUNCTIONS
(B CODES)
Explanations
D Valid data range
D Specification
Restrictions