B-66264EN/01 APPENDIX E.PARAMETERS
- 105 -
9016 G code for calling program number 9013 as a macro
9017 G code for calling program number 9014 as a macro
9018 G code for calling program number 9015 as a macro
9019 G code for calling program number 9016 as a macro
9020 G code for calling program number 9017 as a macro
9021 G code for calling program number 9018 as a macro
9022 G code for calling program number 9019 as a macro
[Data type] Integer
[Valid data range] -9999 to 9999
Set a G code for calling each of program numbers 9010 to 9019 as a
macro.
(When a negative value is set, modal call is performed.)
9023 M code for calling program number 9020 as a macro
9024 M code for calling program number 9021 as a macro
9025 M code for calling program number 9022 as a macro
9026 M code for calling program number 9023 as a macro
9027 M code for calling program number 9024 as a macro
9028 M code for calling program number 9025 as a macro
9029 M code for calling program number 9026 as a macro
9030 M code for calling program number 9027 as a macro
9031 M code for calling program number 9028 as a macro
9032 M code for calling program number 9029 as a macro
[Data type] Integer
[Valid data range] 1 to 99999999
Set a M code for calling each of program numbers 9020 to 9029 as a
macro.