7.UNITS B-70315EN/02
- 188 -
Code Name of function
Initial
value
Setting
value
Remarks
C001 Intelligent input terminal 1 selection 18 18
C002 Intelligent input terminal 2 selection 16 15
C003 Intelligent input terminal 3 selection 06 07
C004 Intelligent input terminal 4 selection 11 11
C005 Intelligent input terminal 5 selection 09 09
C006 Intelligent input terminal 6 selection 03 03
C007 Intelligent input terminal 7 selection 02 02
C008 Intelligent input terminal 8 selection 01 01
01: RV (reverse rotation), 02: CF1 (multistage speed 1), 03:
CF2 (multistage speed 2), 04: CF3 (multistage 3), 05: CF4
(multistage speed 4), 06: JG (jogging), 07: DB (external
direction current damping), 08: SET (second damping), 09:
2CH (2-stage acceleration/deceleration), 11: FRS (free run),
12: EXT (external trip), 13: USP (restart prevention function at
power supply recovery time), 14: CS (commercial switching),
15: SFT (soft lock), 16: AT (analog in switching), 18: RS
(reset), 20: STA (3-wire activation), 21: STP (3-wire hold), 22:
F/R (3-wire forward/reverse), 23: PID (PID enable/ disable),
24: PIDC (PID integral reset), 27: UP (remote operation
speedup), 28: DWN (remote operation slowdown), 29: UDC
(remote operation data clear), 31: OPE (forced operation), 32
to 38: SF1 to SF7 (multistage speed bits 1 to 7), 39:
OLR(Overload limit switching), no: NO (No assignment)
C011 Intelligent input 1a/b selection 00 00
C012 Intelligent input 2a/b selection 00 00
C013 Intelligent input 3a/b selection 00 00
C014 Intelligent input 4a/b selection 00 00
C015 Intelligent input 5a/b selection 00 00
C016 Intelligent input 6a/b selection 00 00
C017 Intelligent input 7a/b selection 00 00
C018 Intelligent input 8a/b selection 00 00
Intelligent
(INT) input
terminal
C019 FWa/b selection 00 00
00:NO, 01:NC
C021 Intelligent output terminal 11 selection 01 01
C022 Intelligent output terminal 12 selection 00 00
C023 Intelligent output terminal 13 selection 03 03
C024 Intelligent output terminal 14 selection 02 02
C025 Intelligent output terminal 15 selection 08 08
INT output
terminal
C026 Alarm relay output terminal 05 05
00: RUN (during operation), 01: FA1 (when constant speed is
reached), 02: FA2 (more than set frequency), 03: OL (advance
notice of overload), 04: OD (excessive PID deviation), 05: AL
(trip signal), 06: FA3 (setting frequency only), 08: IP (during
momentary stop), 09: UV (insufficient voltage), 11: RNT (run
time exceeded), 12: ONT (ON time exceeded), 13: THM
(thermal warning)
C027 FM selection 00 00
00: Output frequency, 01: Output current, 03: Digital output
frequency, 04: Output voltage, 5: Output power, 06: Thermal
load ratio, 07: LAD frequency
C028 AM selection 00 00
Monitor
terminal
C029 AMI selection 00 00
00: Output frequency, 01: Output current, 04: Output voltage,
05: Output power, 06: Thermal load ratio, 07: LAD frequency
C031 Intelligent output 11a/b selection 00 00
C032 Intelligent output 12a/b selection 00 00
C033 Intelligent output 13a/b selection 00 00
C034 Intelligent output 14a/b selection 00 00
C035 Intelligent output 15a/b selection 00 00
C036 Alarm relay output a/b selection 01 01
00:NO, 01:NC
C040
Overload advance notice signal output
mode selection
01 01
00: During acceleration/deceleration or during constant-speed
operation, 01: During constant-speed operation only
C041 Overload advance notice level 24A (46A) 24A (46A)
0.0 to 2*(rated current)
C042 Acceleration reach frequency 0.00Hz 0.00Hz
C043 Deceleration reach frequency 0.00Hz 0.00Hz
0.00 to 1500
Level
output
terminal
state
C044 PID deviation excess level 3.0% 3.0%
0.0 to 100.0
C070 Data command selection 02 02
02: Operator, 03: RS485, 04: Option 1, 05: Option 2
C071 Communication rate selection 04 04
03:2400bps, 04:4800bps, 05:9600bps, 06:19200bps
C072
Communication station number
selection
1 1
1 to 32
C073 Communication bit length selection 7 7
7: 7 bits, 8: 8 bits
C074 Communication parity selection 00 00
00: With no parity, 01: Even parity, 02: Odd parity
C075 Communication stop bit selection 1 1
1: 1 bit, 2: 2 bits
Communi-
cation
function
adjustment
C078 Communication wait time 0ms 0ms
0 to 1000
C081 0 adjustment
Factory-
adjusted
Factory-
adjusted
C082 01 adjustment
Factory-
adjusted
Factory-
adjusted
C083 02 adjustment
Factory-
adjusted
Factory-
adjusted
C085 Thermistor adjustment 105.0 105.0
0.0 to 1000
C086 AM offset adjustment 0.0V 0.0V
0.0 to 10.0
C087 AMI adjustment 80 80
0 to 255
Analog
meter
setting
C088 AMI offset adjustment
Factory-
adjusted
Factory-
adjusted