B-70315EN/02 APPENDIX E.PARAMETER LIST
- 309 -
E.6 PARAMETERS FOR HIGH-SPEED PIERCING
CONDITIONS
15080 High-speed piercing power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
Set the high-speed piercing power.
15081 Initial high-speed piercing frequency
[Data type] Word
[Unit of data] Hz
[Valid data range] 5 to 2000
Set the initial high-speed piercing frequency.
15082 Incremental high-speed piercing frequency
[Data type] Word
[Unit of data] Hz
[Valid data range] 0 to 2000
Set the incremental high-speed piercing frequency.
15083 Initial high-speed piercing duty ratio
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 100
Set the initial high-speed piercing duty ratio.
15084 Incremental high-speed piercing duty ratio
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 100
Set the incremental high-speed piercing duty ratio.
15085 High-speed piercing step time
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
Set the high-speed piercing step time.