OPERATIONB–63534EN/02 11. SETTING AND DISPLAYING DATA
1015
Displays the program input from the MDI and modal data in the MDI
mode.
Procedure for displaying the program screen for MDI operation
1 Press function key
PROG
.
2 Press chapter selection soft key
[MDI].
The program input from the MDI and modal data are displayed.
O0000 G00 X100.0 Z200.0 ;
M03 ;
G01 Z120.0 F500 ;
M98 P9010 ;
G00 Z0.0 ;
%
G00 G90 G94 G40 G80 G50 G54 G69
G17 G22 G21 G49 G98 G67 G64 G15
H M
T D
F S
> _ S 0 T0000
MDI **** *** *** 16:05:59
[ PRGRM ] [ MDI ] [ CURRNT ] [ NEXT ] [ (OPRT) ]
PROGRAM (MDI) O2000 N00130
Program
Modal information
See III–4.2 for MDI operation.
The modal data is displayed when bit 7 (MDL) of parameter 3107 is set
to 1. Up to 16 modal G codes are displayed. On the 12 soft keys display
unit, however, the contents of the program are displayed on the right half
of the screen and the modal data is displayed on the left half of the screen,
regardless of this parameter.
During automatic operation, the actual speed, SACT, and repeat count are
displayed. The key input prompt (>_) is displayed otherwise.
11.2.5
Program Screen for
MDI Operation
Procedure
Explanations
D MDI operation
D Modal information
D Displaying during
automatic operation