OPERATION
4. AUTOMATIC OPERATION
B–63534EN/02
818
(a) INPUT UNIT : Handle interrupt move amount in input unit
system
Indicates the travel distance specified by handle
interruption according to the least input
increment.
(b) OUTPUT UNI : Handle interrupt move amount in output unit
system
Indicates the travel distance specified by handle
interruption according to the least command
increment.
(c) RELATIVE : Position in relative coordinate system
These values have no effect on the travel distance
specified by handle interruption.
(d) DISTANCE TO GO : The remaining travel distance in the current
block has no effect on the travel distance
specified by handle interruption.
The handle interrupt move amount is cleared when the manual reference
position return ends every axis.
Systems having five or more axes provide the same display as the overall
position display. See III–11.1.3.
D Display for five–axis
systems or better