OPERATION
B–63534EN/02
11. SETTING AND DISPLAYING DATA
1075
A measurement probe, fitted with a sensor, can also be used to measure
the Z–axis workpiece origin offset or measure the X–/Y–axis workpiece
origin offset based on a surface, in the same way as when measuring the
X–/Y–axis workpiece origin offset based on a hole. By inputting a skip
signal as soon as the probe touches the workpiece surface, feed is
automatically stopped. Subsequently, apply the same procedure as that
for each measurement.
There are the following screens for the fixture offset function: Screen for
checking the currently selected fixture offset value (fixture offset (ACT)
screen) and screen for setting and checking eight groups of fixture offset
values (fixture offset screen).
Procedure for displaying the fixture offset (ACT) screen
1 Press function key
OFFSET
SETTING
.
2 Press continuous menu key
several times until [F–ACT]
appears.
3 Press soft key
[F–ACT].
The following fixture offset (ACT) screen appears:
FIXTURE OFFSET (ACT)
ACT(P=01)
X 0.000
Y 0.000
Z 0.000
C 0.000
B 0.000
A 0.000
[ ] [ ] [ ] [ ] [ ]
This screen displays the currently selected fixture offset number (P) and
fixture offset vector data.
D Using a skip signal
11.4.15
Displaying and Setting
Rotary Table Dynamic
Fixture Offset
Procedure
Explanations
F-ACT
Continuous menu key