Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
Date
Design
Descri
tion
Date
FANUC Series 16i–MB, 18i–MB, 18i–MB5
Nano Smoothing Specification
Dec.27.2001
Sheet
T.Horie
14/14
A-78975E
19582 Minimum moved distance of block judged according to the angle difference
between blocks of Nano Smoothing
[Input Type] Parameter Input
[Data Type] 2 Word Type
[Unit of Data]
Increment System IS-A IS-B IS-C Unit
Mm input 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
[Minimum Data Unit] Depend on the increment system of the reference axis
[Valid data range] 0
~
+99999999
Minimum moved distance of the block judged according to the angle
difference between blocks of the Nano Smoothing is set. When the
length specified in a block is shorter than this setting, the judgment by the
angle difference is not done.
When this parameter setting is 0, the judgment by the angle difference is
effective in all blocks. It is necessary to set bigger value than that of the
minimum moved distance parameter (No.8490) to block in doing the Nano
smoothing.