OPERATION
11. SETTING AND DISPLAYING DATA
B–63534EN/02
1078
S Move the cursor to the parameter number using the page keys,
PAGE
and
PAGE
, and cursor keys, , , , and .
5 To set the parameter, enter a new value with numeric keys and press
soft key
[INPUT]. The parameter is set to the entered value and the
value is displayed.
6 Set 0 for
PARAMETER WRITE to disable writing.
Procedure for enabling/displaying parameter writing
1 Select the MDI mode or enter state emergency stop.
2 Press function key
OFFSET
SETTING
.
3 Press soft key
[SETING] to display the setting screen.
SETTING (HANDY) O0001 N00000
> _ S 0 T0000
MDI **** *** *** 16:05:59
[ OFFSET ] [ SETING ] [ WORK ] [ ] [ (OPRT) ]
PARAMETER WRITE = 1 (0:DISABLE 1:ENABLE)
TV CHECK = 0 (0:OFF 1:ON)
PUNCH CODE = 1 (0:EIA 1:ISO)
INPUT UNIT = 0 (0:MM 1:INCH)
I/O CHANNEL = 0 (0–3:CHANNEL NO.)
SEQUENCE NO. = 0 (0:OFF 1:ON)
TAPE FORMAT = 0 (0:NO CNV 1:F10/11)
SEQUENCE STOP = 0 (PROGRAM NO.)
SEQUENCE STOP = 11(SEQUENCE NO.)
4 Move the cursor to PARAMETER WRITE using cursor keys.
5 Press soft key
[(OPRT)], then press [ON :1] to enable parameter
writing.
At this time, the CNC enters the P/S alarm state (No. 100).
6 After setting parameters, return to the setting screen. Move the cursor
to
PARAMETER WRITE and press soft key [(OPRT)] , then press
[OFF :0].
7 Depress the
RESET
key to release the alarm condition. If P/S alarm No.
000 has occurred, however, turn off the power supply and then turn it
on, otherwise the P/S alarm is not released.
See III–8 for setting parameters with external input/output devices such
as the Handy File.
Explanations
D Setting parameters with
external input/output
devices