6. AC SPINDLES
B–63325EN/03
350
The standard motor parameters for each model can be set up
automatically.
* Because the way each motor is controlled varies with the specification
determined by the machine tool builder, this function sets a standard
(initial) value for any parameter specified by the machine tool builder.
Therefore, automatic operation requires that the parameters be set up
correctly according to the parameter list (No. 3000 to No. 3393).
1 Switch the power on with the machine at an emergency stop.
2 Reset the PLD parameter (bit 0 of parameter 5607) to 0.
#7
5607
#6 #5 #4 #3 #2 #1 #0
PLD
0#(PLD) Specifies whether to perform automatic setting for the serial interface
spindle parameters.
1 : Not to perform automatic setting.
0 : To perform automatic setting.
3 Specify the motor model.
3133 Motor model code
Code Motor model Amplifier
100 α 0.5 (3000/8000min
–1
) SPM–2.2
101 α 1 (3000/8000min
–1
) SPM–2.2
102 α 1.5 (1500/8000min
–1
) SPM–5.5
103 α 2 (1500/8000min
–1
) SPM–5.5
104 α 2/1500 (3000/1500min
–1
) SPM–5.5
105 α 3 (1500/8000min
–1
) SPM–5.5
106 α 6 (1500/8000min
–1
) SPM–11
107 α 8 (1500/6000min
–1
) SPM–11
108 α 12 (1500/6000min
–1
) SPM–15
109 α 15 (1500/6000min
–1
) SPM–22
110 α 18 (1500/6000min
–1
) SPM–22
111 α 22 (1500/6000min
–1
) SPM–26
112 α P8 (750/6000min
–1
) SPM–11
113 α P12 (750/6000min
–1
) SPM–11
114 α P15 (750/6000min
–1
) SPM–15
115 α P18 (750/6000min
–1
) SPM–15
116 α P22 (750/6000min
–1
) SPM–22
117 α P30 (575/4500min
–1
) SPM–22
4 Switch the power off and on again.
The parameters (No. 3000 to No. 3393) are loaded, and the PLD
parameter (bit 0 of parameter No. 5607) is set to 1.
6.1.3
Automatic Setting of
Standard Parameters