PROGRAMMING
B–64134EN/01
13. FUNCTIONS TO SIMPLIFY
PROGRAMMING
173
Metric input Inch input Remark
G98 1 mm/min 0.01inch/min Decimal point allowed
G99 0.01mm/rev 0.0001inch/rev Decimal point allowed
Tapping axis feedrate: 1000 mm/min
Spindle speed: 1000 min
–1
Screw lead: 1.0 mm
<Programming for feed per minute>
G98 ; Command for feed per minute
G00 X100.0 ; Positioning
M29 S1000 ; Command for specifying rigid mode
G84 Z–100.0 R–20.0 F1000 ; Rigid tapping
<Programming for feed per rotation>
G99 ; Command for feed per rotation
G00 X100.0 ; Positioning
M29 S1000 ; Command for specifying rigid mode
G84 Z–100.0 R–20.0 F1.0 ; Rigid tapping
The rigid tapping cycle is canceled.
For how to cancel this cycle, please see II–13.3.4.
NOTE
When Rigid Tapping Cancel is commanded, the S
command, which is used at rigid tapping, is also cleared. (It
is the same that S0 is commanded.)
Therefore, the S command, which is specified for rigid
tapping, can not be used at blocks after Rigid Tapping
Cancel. Please re–specify S command after Rigid Tapping
Cancel if necessary.
D Units for F
Examples
13.6.2
Rigid Tapping Cancel
(G80)