APPENDIX
B–64134EN/01
G. ALARM LIST
763
No. DescriptionFaulty location and remedy
SVPM
STATUS1
indica-
tion(*1)
Message
9120 C0 1 Replace the communication
cables between the CNC and
SPM.
2 Replace the SPM control
printed circuit board.
3 Replace the spindle interface
printed circuit board in the CNC.
Communication data alarm
9121 C1 1 Replace the communication
cables between the CNC and
SPM.
2 Replace the SPM control
printed circuit board.
3 Replace the spindle interface
printed circuit board in the CNC.
Communication data alarm
9122 C2 1 Replace the communication
cables between the CNC and
SPM.
2 Replace the SPM control
printed circuit board.
3 Replace the spindle interface
printed circuit board in the CNC.
Communication data alarm
ERROR CODES (SERIAL SPINDLE)
NOTE*1
The SVPM indicates an error code as a 2–digit number in
STATUS1 when the yellow LED is on. Error codes appear
in CNC diagnostic data No. 712.
When the red LED is on, the SVPM indicates the number of
an alarm generated by the serial spindle, providing a
different meaning from when the yellow LED is on.
³ See “Alarms (Serial Spindle).”
SVPM
STATUS1
indica-
tion(*1)
Description Faulty location and remedy
01 When neither *ESP (emergency stop signal; there
are two types of signals: input signal and SVPM
contact signal(*2)) nor MRDY (machine ready sig-
nal) is input, SFR (forward rotation command),
SRV (reverse rotation command), or ORCM
(orientation command) is input.
Check the *ESP and MRDY sequences. For MRDY, pay
attention to the parameter setting (bit 0 of parameter No.
4001) regarding the use of the MRDY signal.
03 When the parameter settings are made not to use
the position sensor, meaning that position control
is not performed (bits 3, 2, 1, 0 of parameter No.
4002 = 0, 0, 0, 0), a Cs contour control command
is input. In this case, the motor is not excited.
Check the parameter settings.