APPENDIXG. ALARM LIST
B–64134EN/01
746
Number ContentsMessage
5040 CAN NOT COMMANDED B–AXIS
MOVE
The machine could not move about the B–axis because parameter
No.8250 was incorrectly specified, or because the PMC axis system
could not be used.
5041 CAN NOT COMMANDED G110
BLOCK
Blocks containing the G110 codes were successively specified in tool–
tip radius compensation for the B–axis.
5046 ILLEGAL PARAMETER (ST.COMP) Parameters related to straightness compensation have been erro-
neously specified. Possible causes are as follows :
1 Invalid axis numbers have been assigned to move or compensation
axes.
2 The number of pitcherror compensation points between the maxi-
mum positive and maximum negative points exceeds 128.
3 Straightness compensation point numbers have been assigned in
other than ascending order.
4 Straightness compensation points could not belocated between the
maximum positive and maximum negative pitch error compensation
points.
5 The amount of compensation per compensation point is too large or
too small.
5059 RADIUS IS OUT OF RANGE During circular interpolation, the center of the arc specified with I, J,
and K caused the radius to exceed nine digits.
5073 NO DECIMAL POINT A decimal point is not specified for a command for which a decimal point
must be specified.
5074 ADDRESS DUPLICATION ERROR The same address appears more than once in a block. Alternatively, a
block contains two or more G codes belonging to the same group.
5134 FSSB : OPEN READY TIME OUT Initialization did not place FSSB in the open ready state.
5135 FSSB : ERROR MODE FSSB has entered error mode.
5136 FSSB : NUMBER OF AMPS IS SMALL In comparison with the number of controlled axes, the number of amplifi-
ers recognized by FSSB is not enough.
5137 FSSB : CONFIGURATION ERROR FSSB detected a configuration error.
5138 FSSB : AXIS SETTING NOT COM-
PLETE
In automatic setting mode, axis setting has not been made yet.
Perform axis setting on the FSSB setting screen.
5139 FSSB : ERROR Servo initialization did not terminate normally.
The optical cable may be defective, or there may be an error in connec-
tion to the amplifier or another module.
Check the optical cable and the connection status.
5197 FSSB : OPEN TIME OUT The CNC permitted FSSB to open, but FSSB was not opened.
5198 FSSB : ID DATA NOT READ Temporary assignment failed, so amplifier initial ID information could not
be read.
5212 SCREEN COPY : PARAMETER
ERROR
There is a parameter setting error. Check that 4 is set as the I/O channel
(parameter No. 0020).
5213 SCREEN COPY :
COMMUNICATION ERROR
The memory card cannot be used. Check the memory card. (Check
whether the memory card is write–protected or defective.)
5214 SCREEN COPY : DATA TRANSFER
ERROR
Data transfer to the memory card failed.
Check whether the memory card space is insufficient and whether the
memory card was removed during data transfer.
5220 REFERENCE POINT
ADJUSTMENT MODE
A parameter for automatically set a reference position is set. (Bit 2 of
parameter No. 1819 = 1)
Perform automatic setting.
(Position the machine at the reference position manually, then perform
manual reference position return.)