5. Program restart for Dynamic Diameter/Radius switch function (M series)
In case that program restart is performed on the program using Dynamic
Diameter/Radius switch function, set parameter DRM (No.13114#6) to 1.
And Diameter/Radius mode must be switched by two M codes, which are
specified in parameter No.3419 (M code for Diameter mode) and No.3420
(M code for Radius mode).
In searching a target block of program restart, Diameter/Radius mode is
decided by the above M codes. However, the mode is considered as Radius
mode before the first M code appears.
Caution
- Parameter DRM can be used in case that Dynamic
Diameter/
Radius switch is used for only the first axis.
- Parameters No.3419 and No.3420 are effective also as M
code preventing buffering.