SQB Program restart by specifying a block number is
0: Available
1: Not available
SQP Program restart P-Type is
0: Available
1: Not available
#7 #6 #5 #4 #3 #2 #1 #0
13421 FRF FCN FRS
[Data type] Bit
FRS Program restart at the program with the M code which changes
synchronization mode of flexible synchronous control is
0: Disabled
1: Enabled
FCN When emergency stop or servo off occurs, the flexible synchronous
control is
0: Canceled
1: Not canceled.
FRF When G27/G28/G29/G30/G30.1/G53 is commanded in the flexible
synchronization mode,
0: P/S Alarm 10 occurs.
1: If G28 is commanded for a master axis, the reference point of which
is not established, or if G27/G28/G29/G30/G30.1 /G53 is commanded
for a slave axis, P/S Alarm 5381 occurs.