3419 M-code of diameter mode
[Data type] Byte
[Valid Data range] 1 to 255
It is recognized that the first axis is a diameter mode during the program
search of program restart when parameter DRM (No.13114#6) is set to
"1".
Value 0 is invalid.
3420 M-code of radius mode
[Data type] Byte
[Valid Data range] 1 to 255
It is recognized that the first axis is a radius mode during the program
search of program restart when parameter DRM (No.13114#6) is set to
"1".
Value 0 is invalid.
#7 #6 #5 #4 #3 #2 #1 #0
13117 SQP SQB PMP INT
[Data type] Bit
INT During program restart, Interference check for cutter compensation C
(M series) or tool nose radius compensation (T series) is
0: Performed
1: Not performed
PMP For MDI program output by program restart, memory protection signal
(KEY3 or KEY1) is
0: Not effective
1: Effective.
Caution
When parameter KEY (No.3290#7) is set to 0, signal KEY3
is available for MDI program protection, and when KEY is
set to 1, signal KEY1 is available.
Edit
17/22
Data Si
nature
Descri
tion
Improvement of Program restart Specifications
A-90024EN
Drawing No.
Page
Modification
02
Date
Mar/26/05.
Desig.
M. Kobayashi
Apprv.
T. Endo
May/10/05.
FANUC Series 16i/18i/21i-MB/TB
Title