Program restart MDI program output completed signal
SQMPR<F316#6>
[Classification] Output signal
[Function] Indicates M/S/T/B codes output into MDI program is completed.
[Operation] The program restart MDI program output completed signal becomes “1”
when:
- M/S/T/B codes output into MDI program is completed in program
restart.
Caution
- If there is no M/S/T/B code to be output, MDI program is not
made. In this case, SQMPR does not become 1.
This signal is set to “0” when:
- MDI program execution starts.
- Program restart operation is completed before MDI program
execution.
- Reset is done before MDI program execution.
Program restart MDI program execution completed signal
SQMPRE<F316#7>
[Classification] Output signal
[Function] Indicates MDI program execution is complete.
[Operation] The program restart MDI program execution completed signal is
becomes “1” when:
- MDI program execution in program restart is completed.
This signal is set to “0” when:
- MEM mode is selected after MDI program execution.
- Reset is done before after MDI program execution.
Caution
“Improvement of Program restart” option is required to use signals
SQMPR and SQMPRE.