2. Program restart for Flexible synchronous control (FS16i/18i-B)
2.1 General
Program restart function is enabled at the program with the M code
which changes synchronization mode of flexible synchronous control.
2.2 Details
2.2.1 Setting of parameter
When parameter FRS (No.13421#0) is set to "1", Program restart
function is enabled at the program with the M code which changes
synchronization mode of flexible synchronous control.
(When parameter FRS (No.13421#0) is set to "0", P/S alarm No.5422
occurs at restarting program with the M code which changes
synchronization mode of flexible synchronous control.)
2.2.2 Caution in making/executing program
(1) When this function is effective, the command to slave axis in
synchronization mode is not available. If commanded, P/S alarm
No.5376 occurs.
(Example)
C : Master axis, A : Slave axis
O0001 ;
N10 C0 A0 ;
N20 M133 ; <------- Synchronization mode ON
N30 C10. A5. ; -------> P/S alarm No.5376
N40 C20. ;
N50 M136 ; <------- Synchronization mode OFF
N60 G90 A20. ;
N70 G91 A10. ;
:
(2) When the synchronization is canceled, the work coordinate of slave
axis is preset.
Edit
9/22
Data Si
nature
Descri
tion
Improvement of Program restart Specifications
A-90024EN
Drawing No.
Page
Modification
02
Date
Mar/26/05.
Desig.
M. Kobayashi
Apprv.
T. Endo
May/10/05.
FANUC Series 16i/18i/21i-MB/TB
Title