6. SPINDLE CONNECTION
B–63003EN/04
138
Cable connection between the serial spindle connector panel and a spindle
amplifier
(Interconnection cable 2)
:SIN
SOUT
7
:SIN
SOUT
JA7B
(PCR–EV20MDT)
0V
0V
0V
19
20
SIN
:SOUT
1
3
2
4
6
5
8
7
9
10
Serial spindle connector panel
JA7A–1, 2
(PCR–E20MD)
α spindle amplifier module
0V
0V
0V
11
13
12
14
16
15
18
17
19
20
SIN
:SOUT
1
3
2
4
6
5
8
9
10
(+5V)
(+5V)
(+5V)
(+5V)
(+5V)
(+5V)
16
15
18
17
11
13
12
14
NOTE
When an optical cable is used for the connection between
the CNC and a spindle, the +5V signals indicated in
parentheses are used to feed power to the optical I/O link
adapter. Do not connect these signals when an optical
cable is not used.
1
2
3
4
12
14
16
SOUT
*SOUT
SIN
*SIN
0V
0V
0V
SIN
*SIN
SOUT
*SOUT
0V
0V
0V
Ground plate
Shield
JA4A–1, 2
Cable connection
JA7B
3
4
1
2
12
14
16
Recommended wire specification:
A66L–0001–0284#10P (#28AWG × 10 pairs)
NOTE
When this cable is installed close to other cables such as a
power line, a shielded wire needs to be connected to the
ground plate. When the serial spindle connector panel is
installed close to the spindle amplifier module, a connection
to the ground plate is unnecessary.