B–63003EN/04
10. CONNECTION TO FANUC I/O Link
299
DInx General–purpose DI LM Load meter voltage
DOnx General–purpose DO SM Speed meter voltage
*ESP Emergency stop 0M LM/SM reference voltage (0V)
ECM1 *ESP common signal *KYDx Matrix DI data signal
OTR OT release *KYCx Matrix DI common signal
ECM2 OTR common signal *LDx Matrix DO data signal
EON/OF Power ON/OFF control signal LCnL/H Matrix DO common signal
COM EON/EOF common signal *MNDI Three DI points acceptable
HAI Input from manual pulse generator *BZMD Buzzer off
HBI Input from manual pulse generator
See Subsec. 10.7.4 for details of connection and signal meanings.
+5E
RV
DI00 to DI37
0V
Input signal specifications
Contact rating
5VDC, 3.2mA or higher
Leakage current between open contacts 0.2mA or lower (5 VDC)
Voltage drop across closed contacts 0.75V or lower
10.7.4
Interface
General–purpose DI