A-76286E
Sheet
Title
Draw
No.
16 Apr.19.'04 Addition or Modification of 16)
15 Jul.02.'02 Y.Takeuchi Improvement of status display T.Endo
14 Jun.21.'02 Y.Takeuchi Improvement of status display T.Endo
13 May.27.'02 Y.Takeuchi Addition of status display and improvement of S/T code output T.Endo
12 Mar.18.'02 Y.Takeuchi Availability of direction change movement in auxiliary function T.Endo
11 Jan.22.'02 Y.Takeuchi Availability of Angular axis control and Advanced preview control T.Endo
10 Oct.03.'01 Y.Takeuchi Addition or Modification of "5. About function improvement" T.Endo
Ed.. Date Design Description
Date May.02.’97 Desig. K.Ishida Apprv. T.Nakazato
FANUC Series 16i/18i/21i-TB/TB
Manual Handle Retrace
Specifications
24/40
5.5 The improvement about the execution of measurement G code at the speed of override
100%
5.5.1 Specifications
When the parameter MGO(No.6400#6) is set to "1", handle pulse is invalid and it is always
executed at 100% override. When the parameter MGO(No.6400#6) is set to "0", this function
is invalid and handle pulse is valid.
In multi path system, this function does not effect the execution of another path and handle
pulse is valid in another path.
The measurement G code to which this function is effective is as follows.
1) G31 of skip
2) G31, G31P1, G31P2, G31P3, G31P4, G04, G04Q1, G04Q2, G04Q3 and G04Q4 of
multistage skip
3) G31P99 and G31P98 of torque limit skip
When the measurement by G36 and G37 of automatic tool compensation (when parameter
G36(No.3405#3) is set to "1", G code of automatic tool compensation are G37.1 and G37.2.) is
executed, handle pulse is invalid and it is always executed at 100% override regardless of
setting the parameter MGO(No.6400#6). At the rapid traverse before measurement, handle
pulse is valid.
And parameter SKF(No.6200#7) is set to "0", handle pulse at G31 is invalid and it is always
executed at 100% override regardless of setting the parameter MGO(No.6400#6).
When parameter MG4(No.6400#6) is set to "1" and the software option of multistage skip is
enabled and the setting of parameter No.6202 to No.6206 is enabled, backward movement
prohibition is enabled in G04 block of multistage skip.
Besides, please refer to the clause 5.5.3 about software series and edition which this
improvement is applied.
10)