PROGRAMMING
B–61404E/08
16. CUSTOM MACRO B
304
Settings can be read and written. Binary values are converted to
decimals.
REVX : X–axis mirror image on/off
REVY : Y–axis mirror image on/off
TVON : TV check on/off
ISO : Output code, EIA/ISO
INCH : Metric input/inch input
ABS : Incremental programming/absolute programming
SEQ : Sequence–number automatic insertion on/off
REV4 : Fourth axis mirror image on/off
TAPE : F10/11 tape format on/off
#15 #14 #13 #12 #11 #10 #9 #8
TAPE REV4
Setting
#7 #6 #5 #4 #3 #2 #1 #0
SEQ
ABS
INCH ISO TVON REVY REVX
Setting
#3005
The number (target number) of parts required and the number (completion
number) of machined parts can be read and written.
Table 16.2 (h) System variables for the number of parts required and the
number of machined parts
Variable number
Function
#3901 Number of machined parts (completion number)
#3902 Number of required parts (target number)
NOTE
Do not substitute a negative value.
D Settings
D Number of machined
parts