B–61404E/08
11. SETTING AND DISPLAYING DATAOPERATION
581
If a block containing a specified sequence number appears in the program
being executed, operation enters single block mode after the block is
executed.
Procedure for sequence number comparison and stop
1 Select the MDI mode.
2 Press function key
DGNOS
PARAM
.
3 Press soft key
[PARAM].
4 Press page key
or several times until the following screen
is displayed.
PARAMETER O1224 N0000
[ PARAM ][ DGNOS ][ ][ SV–PRM ][ ]
(SETTING 2)
PWE = 1 (0:DISABLE 1:ENABLE)
REV4 = 0
TAPEF = 0
(SEQUENCE STOP)
PRGNO = 0
SEQNO = 0
PART TOTAL = 17
PART REQUIRED = 50
PART COUNT = 17
RUN TIME OH 4M CYCLE TIME OH OM 2S
NO. PWE = S 0 T
03:35:07 MDI
5 Enter in (PRGNO) for SEQUENCE STOP the number (1 to 9999) of
the program containing the sequence number with which operation
stops.
6 Enter in
(SEQNO) for SEQUENCE STOP (with four or less digits)
the sequence number with which operation is stopped.
7 When automatic operation is executed, operation enters single block
mode at the block containing the sequence number which has been
set.
11.5.4
Sequence Number
Comparison and Stop