12.SETTING AND DISPLAYING DATA OPERATION B-63944EN/02
- 1302 -
Table 12.4.12 (d) Parameters displayed for parameter tuning (3)
Menu Group Parameter
No.
Name Brief description
Standard
setting
AXIS
SETTING
Basic 1001#0 INM Least command increment on linear axes:
0:Metric (millimeter machine) 1:Inch (inch machine)
1005#0 ZRNx When an automatic operation (other than G28) is executed before
reference position return:
0:Alarm is issued (No.224) 1:No alarm is issued.
0
1005#1 DLZx Reference position return without dogs: 0:Disabled 1:Enabled
1006#0 ROTx Setting of linear axes or rotary axis:
0:Linear axis 1:Rotation axis
1006#3 DIAx Setting of the amount of travel:
0:Radius specification 1: Diameter specification
1006#5 ZMIx Reference position return direction:
0:Plus direction 1:Minus direction
1008#0 ROAx Rotation axis roll-over function: 0:Disabled 1:Enabled 1
1008#2 RRLx With the amount of travel per revolution, relative coordinates are:
0:Not rounded 1:Rounded
1
1013#0 ISAx Sets the least input increment and least command increment:
0:IS-B 1:IS-A
1013#1 ISCx Sets the least input increment and least command increment:
0:IS-B 1:IS-C
1013#2 ISDx Sets the least input increment and least command increment:
0:IS-B 1:IS-D
1013#3 ISEx Sets the least input increment and least command increment:
0:IS-B 1:IS-E
1020 Program name *1
1022 Sets each axis in the basic coordinate system. *2
1023 Servo axis number
1815#1 OPTx A separate pulse coder is: 0:Not used 1:Used
1815#4 APZx The correspondence between machine positions and
absolute-position detector positions is: 0:Not established
1:Established
1815#5 APCx The position detector used is: 0:Other than an absolute-position
detector 1:Absolute-position detector
1825 Servo loop gain
1826 Effective area
1828 Positional deviation limit during travel
1829 Positional deviation limit during stop 500
*1 : For the M series: 88(X),89(Y),90(Z) sequentially starting with the
first axis (no standard value for the fourth axis and
up)
For the T series: 88(X),90(Z) (no standard value for the third axis
and up)
*2 : For the M series: 1,2,3 sequentially starting with the first axis (no
standard value for the fourth axis and up)
For the T series: 1,3 (no standard value for the third axis and up)