A.PARAMETERS APPENDIX B-63944EN/02
- 1396 -
Example of setting)
Separate detector connection destination Parameter setting
Controlled
axis
Connectors
for 1st unit
Connectors
for 2nd unit
Connectors
for 3rd unit
Connectors
for 4th unit
No.
1936
No.
1937
No.
1938
No.
1939
No.1905
(#7,#6,#2,#1)
X1 JF101 - - - 0 - - - 0,1,0,0
Y1 - JF102 - - - 1 - - 1,0,0,0
Z1 - - JF102 - - - 1 - 0,0,0,1
X2 - JF101 - - - 0 - - 1,0,0,0
Y2 - - - JF101 - - - 0 0,0,1,0
Z2 - - - - - - - - 0,0,0,0
A1 - - JF101 - - - 0 - 0,0,0,1
B1 - - - JF102 - - - 1 0,0,1,0
C1 - JF104 - - - 3 - - 1,0,0,0
A2 JF102 - - - 1 - - - 0,1,0,0
B2 - JF103 - - - 2 - - 1,0,0,0
C2 - - - JF103 - - - 2 0,0,1,0
NOTE
When automatic setting mode is selected for FSSB
setting (when the parameter FMD (No.1902#0) is set
to 0), these parameters are automatically set when
input is performed with the FSSB setting screen.
When manual setting 2 mode is selected for FSSB
setting (when the parameter FMD (No.1902#0) is set
to 1), these parameters must be set directly.
Parameters No.2000 to 2999 are for digital servo, The following
parameters are not explained in this manual. Refer to FANUC AC
SERVO MOTOR αi series PARAMETER MANUAL (B-65270EN)
#7 #6 #5 #4 #3 #2 #1 #0
2011 XIAx
[Input type] Parameter input
[Data type] Bit axis
# 7 XIAx Temporary absolute coordinate setting is:
0: Not used.
1: Used.
NOTE
1 When temporary absolute coordinate setting is
used, bit 1 (OPTx) of parameter No. 1815, bit 5
(APCx) of parameter No. 1815, parameter No.
1874, and parameter No. 1875 must be set.
2 The setting of this parameter becomes effective
after the power is turned off then back on.