B-63944EN/02 APPENDIX A.PARAMETERS
- 1413 -
# 7 G23 When the power is turned on
0: G22 mode (stored stroke check on)
1: G23 mode (stored stroke check off)
#7 #6 #5 #4 #3 #2 #1 #0
3404 M3B M02 M30 SBP
[Input type] Parameter input
[Data type] Bit path
# 2 SBP In an external device subprogram call, the address P format is based
on:
0: File number specification
1: Program number specification
NOTE
In memory card operation, the program number
specification format is used, regardless of the
setting of this parameter.
# 4 M30 When M30 is specified in a memory operation:
0: M30 is sent to the machine, and the head of the program is
automatically searched for. So, when the ready signal FIN is
returned and a reset or reset and rewind operation is not
performed, the program is executed, starting from the beginning.
1: M30 is sent to the machine, but the head of the program is not
searched for. (The head of the program is searched for by the
reset and rewind signal.)
# 5 M02 When M02 is specified in memory operation
0: M02 is sent to the machine, and the head of the program is
automatically searched for. So, when the end signal FIN is
returned and a reset or reset and rewind operation is not
performed, the program is executed, starting from the beginning.
1: M02 is sent to the machine, but the head of the program is not
searched for. (The head of the program is searched for by the
reset and rewind signal.)
# 7 M3B The number of M codes that can be specified in one block
0: One
1: Up to three