A.PARAMETERS APPENDIX B-63944EN/02
- 1364 -
1322
Coordinate value I of stored stroke check 2 in the positive direction on each axis
1323
Coordinate value I of stored stroke check 2 in the negative direction on each axis
[Input type] Setting input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Set the coordinate value of stored stroke check 2 on each axis in the +
or - direction in the machine coordinate system.
NOTE
1 Specify diameter values for any axes for which
diameter programming is specified.
2 Whether the inside area or outside area is a
prohibited area is set using bit 0 (OUT) of
parameter No. 1300.
1324
Coordinate value I of stored stroke check 3 in the positive direction on each axis
1325
Coordinate value I of stored stroke check 3 in the negative direction on each axis
[Input type] Setting input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Set the coordinate value of stored stroke check 3 on each axis in the +
or - direction in the machine coordinate system.
NOTE
1 Specify diameter values for any axes for which
diameter programming is specified.
2 The area inside the area set by parameter No.
1324 and No. 1325 is a prohibited area.