4.AUTOMATIC OPERATION OPERATION B-63944EN/02
- 928 -
- Feed hold
When Feed Hold button on the operator's panel is pressed during
memory operation, the tool decelerates to a stop at a time.
- Reset
Automatic operation can be stopped and the system can be made to
the reset state by using
RESET
key on the MDI panel or external reset
signal. When reset operation is applied to the system during a tool
moving status, the motion is slowed down then stops.
- Optional block skip
When the optional block skip switch on the machine operator's panel
is turned on, blocks containing a slash (/) are ignored.
- Cycle start for the multi-path control
For the multi-path control, a cycle start switch is provided for each
path. This allows the operator to activate a single paths to operate
them at the same time in memory operation or MDI operation. In
general, select the path to be operated with the path selection switch
on the machine operator's panel and then press the cycle start button to
activate the selected path. (The procedure may vary with the machine
tool builder. Refer to the appropriate manual issued by the machine
tool builder.)