12.SETTING AND DISPLAYING DATA OPERATION B-63944EN/02
- 1308 -
(3) Axis moving status/dwell status
MTN : Indicates that the axis is moving.
DWL : Indicates the dwell state.
*** : Indicates a state other than the above.
(4) State in which an auxiliary function is being executed
FIN : Indicates the state in which an auxiliary function is being
executed. (Waiting for the complete signal from the PMC)
*** : Indicates a state other than the above.
(5) Emergency stop or reset status
--EMG-- : Indicates emergency stop.(Blinks in reversed display.)
--RESET-- : Indicates that the reset signal is being received.
(6) Alarm status
ALM : Indicates that an alarm is issued. (Blinks in reversed display.)
BAT : Indicates that the battery is low. (Blinks in reversed display.)
Space : Indicates a state other than the above.
NOTE
When one of the following occurs, the battery
alarm state is displayed, indicating that it is time to
replace the battery:
1 The voltage level of the lithium battery (the battery
for CNC backup) becomes low.
2 The voltage level of the backup battery of the
absolute pulse coder becomes low.
(7) Current time
hh : mm : ss - Hours, minutes, and seconds
(8) Program editing status
INPUT : Indicates that data is being input.
OUTPUT : Indicates that data is being output.
SEARCH : Indicates that a search is being performed.
EDIT : Indicates that another editing operation is being
performed (insertion, modification, etc.)
LSK : Indicates that labels are skipped when data is input.
RSTR : Indicates that the program is being restarted
COMPARE : Indicates that a data comparison is being made.
OFST : Indicates that the tool length compensation amount
measurement mode is set (for the machining center
system) or that the tool length compensation amount
write mode is set (for the lathe system).
WOFS : Indicates that the workpiece origin offset amount
measurement mode is set.
AICC1 : Indicates that operation is being performed in the AI
contour control I mode.
AICC2 : Indicates that operation is being performed in the AI
contour control II mode.
MEM-CHK : Indicates that a program memory check is being made.
WSFT : Indicates that the workpiece shift amount write mode is
set.
LEN : Indicates that the active offset value change mode (tool
length offset value of the M series) is set.
RAD : Indicates that the active offset value change mode (tool
radius compensation amount of the M series) is set.