12.SETTING AND DISPLAYING DATA (15INCH) OPERATION B-63944EN/02
- 116 -
Displaying and setting three-dimensional error compensation data
Procedure
1 Set the following parameters:
- First compensation axis for three-dimensional error
compensation : Parmeter (No. 10800)
- Second compensation axis for three-dimensional error
compensation : Parmeter (No. 10801)
- Third compensation axis for three-dimensional error
compensation : Parmeter (No. 10802)
- Number of compensation points for three-dimensional error
compensation (first compensation axis)
Parmeter (No. 10803)
- Number of compensation points for three-dimensional error
compensation (second compensation axis)
Parmeter (No. 10804)
- Number of compensation points for three-dimensional error
compensation (third compensation axis)
Parmeter (No. 10805)
- Compensation point number of the reference position for
three-dimensional error compensation (first compensation
axis) : Parmeter (No. 10806)
- Compensation point number of the reference position for
three-dimensional error compensation (second compensation
axis) : Parmeter (No. 10807)
- Compensation point number of the reference position for
three-dimensional error compensation (third compensation
axis) : Parmeter (No. 10808)
- Magnification for three-dimensional error compensation
(first compensation axis) : Parmeter (No. 10809)
- Magnification for three-dimensional error compensation
(second compensation axis) : Parmeter (No. 10810)
- Magnification for three-dimensional error compensation
(third compensation axis) : Parmeter (No. 10811)
- Compensation interval for three-dimensional error
compensation (first compensation axis)
Parmeter (No. 10812)
- Compensation interval for three-dimensional error
compensation (second compensation axis)
Parmeter (No. 10813)
- Compensation interval for three-dimensional error
compensation (third compensation axis)
Parmeter (No. 10814)
2 Press function key
SYSTEM
.