B-63944EN/02 OPERATION 3.MANUAL OPERATION
- 923 -
- Angular axis control
In case of using the angular axis control, please confirm the
following items.
- It is necessary to use the linear scale with distance-coded
reference marks (serial) for both the perpendicular axis and the
angular axis.
If not, the alarm DS0019 occurs when reference position
establishment is commanded.
- When the reference point establishment of angular and
perpendicular axes are tried, please set parameter 8200#2(AZR)
to '0' and input signal G063#5(NOZAGC) to '0'.
If not, the alarm DS0019 occurs when reference position
establishment is commanded.
- When the reference point of the perpendicular axis is established,
it is necessary to establish the reference point of the angular axis
previously. When the reference point of the angular axis is not
previously established, the alarm DS0020 occurs.
- On angular axis control, if you use automatic setting of
parameter No.1883,1884 on reference point establishment
(parameter DATx No.1819#2=1), please establish reference point
of perpendicular axis after reference point establishment and
return of angular axis.
In manual reference position return, the perpendicular axis cannot be
specified while the angular axis reference point is being established.
The perpendicular axis, if specified, is ignored.