B-63944EN/02 APPENDIX A.PARAMETERS
- 1467 -
Parameter High-speed skip signal
9S1 HDI0
9S2 HDI1
9S3 HDI2
9S4 HDI3
9S5 HDI4
9S6 HDI5
9S7 HDI6
9S8 HDI7
6254 ε value on the X axis during automatic tool compensation (T series)
ε value during automatic tool length measurement (M series) (for the XAE1
and GAE1 signals)
6255 ε value on the Z axis during automatic tool compensation (T series)
ε value during automatic tool length measurement (M series) (for the XAE2
and GAE2 signals)
[Input type] Parameter input
[Data type] 2-word path
[Unit of data] mm, inch, deg (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
These parameters set the relevant ε value during automatic tool
compensation (T series) or automatic tool length measurement (M
series).
NOTE
1 For the M series, when the setting of
parameter No. 6255 or 6256 is 0, the setting
of parameter No. 6254 is used.
2 Set a radius value regardless of whether
diameter or radius programming is specified.
6287 Positional deviation limit in torque limit skip
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 327670
This parameter sets a positional deviation limit for each axis imposed
when torque limit skip is specified. When the actual positional
deviation exceeds the positional deviation limit, the alarm (SV0004) is
issued and an immediate stop takes place.