A.PARAMETERS APPENDIX B-63944EN/02
- 1412 -
# 6 GSB The G code system is set.
# 7 GSC
GSC GSB G code
0 0 G code system A
0 1 G code system B
1 0 G code system C
NOTE
G code system B and G code system C are
optional functions. When no option is selected, G
code system A is used, regardless of the setting of
these parameters.
#7 #6 #5 #4 #3 #2 #1 #0
G23 CLR FPM G91 G01
3402
G23 CLR G91 G19 G18 G01
[Input type] Parameter input
[Data type] Bit path
# 0 G01 G01 Mode entered when the power is turned on or when the control is
cleared
0: G00 mode (positioning)
1: G01 mode (linear interpolation)
# 1 G18 Plane selected when power is turned on or when the control is cleared
0: G17 mode (plane XY)
1: G18 mode (plane ZX)
# 2 G19 Plane selected when power is turned on or when the control is cleared
0: The setting of bit 1 (G18) of parameter No. 3402 is followed.
1: G19 mode (plane YZ)
When this bit is set to 1, set bit 1 (G18) of parameter No. 3402 to 0.
# 3 G91 When the power is turned on or when the control is cleared
0: G90 mode (absolute command)
1: G91 mode (incremental command)
# 4 FPM At power-on time or in the cleared state:
0: G99 or G95 mode (feed per revolution) is set.
1: G98 or G94 mode (feed per minute) is set.
# 6 CLR Reset button on the MDI panel, external reset signal, reset and rewind
signal, and emergency stop signal
0: Cause reset state.
1: Cause clear state.
For the reset and clear states, refer to Appendix in the User's Manual.